Practical Methods of Building Ventilation - It is usually wise to locate the exhaust fans near the area where heat-producing machinery is found in the industrial building. This has the very practical advantage of exhausting this superheated air near its source and preventing a heat build-up in other areas. If side wall locations are to be utilized for air intake or exhaust, it is desirable to consider the prevailing wind direction during the summer season. If the ventilation system can be oriented to take advantage of prevailing winds, the efficiency of the system may be increased considerably, Systems that incorporate roof exhausters are usually not affected by a prevailing wind. |
|
Business Related Topics...
Computer Related Topics...
Entertainment, Recreation & Sports Related Topics...
Health & Fitness Related Topics...
Home & Family Related Topics...
Shopping Related Topics...
Would you like to submit articles to our site? Have a question or a problem?
You are here: DIME Home > Industry > Practical Methods of Building Ventilation
It is usually wise to locate the exhaust fans near the area where heat-producing machinery is found in the industrial building. This has the very practical advantage of exhausting this superheated air near its source and preventing a heat build-up in other areas. If side wall locations are to be utilized for air intake or exhaust, it is desirable to consider the prevailing wind direction during the summer season. If the ventilation system can be oriented to take advantage of prevailing winds, the efficiency of the system may be increased considerably, Systems that incorporate roof exhausters are usually not affected by a prevailing wind.
Author: Susan Terlitski
Date: Jun 22, 2012 - 11:52:37 AM
It is usually wise to locate the exhaust fans near the area where heat-producing machinery is found in the industrial building. This has the very practical advantage of exhausting this superheated air near its source and preventing a heat build-up in other areas. If side wall locations are to be utilized for air intake or exhaust, it is desirable to consider the prevailing wind direction during the summer season. If the ventilation system can be oriented to take advantage of prevailing winds, the efficiency of the system may be increased considerably, Systems that incorporate roof exhausters are usually not affected by a prevailing wind.
Where air velocity is the critical factor in a breeze conditioning system, use of the "long dimension" of the building or room is highly desirable. By moving air through the long dimension, the cross-sectional area is reduced and less air volume is required to obtain the needed air velocity. A vital element in the successful breeze conditioning system is a supply of clean, cooler, fresh air. While such an ideal air supply may not be available, common sense dictates that air being supplied into the building should be from the best available source. Avoid recirculating air that has just been exhausted from the building or another nearby structure.
The noise level in most commercial and industrial buildings has become a highly critical matter. Although the ventilating equipment is only one item in the overall total, its effect should be carefully considered. If the normal noise level in the building is low, the noise level of the ventilating equipment should be low; if the background noise level is high, the amount of noise added by the ventilation system may be insignificant.
The greatest economy that can result from good planning is a breeze conditioning system that achieves its basic purpose. If it does not do the job for which it was designed, then no economy has been achieved. Here are a number of other ways in which good planning can result in substantial savings. Frequently, exhaust fans are obtained and installed to serve a specific need. In many cases, no consideration is given to a method of coordinating this equipment. Process fans may be competing with general exhaust fans; loading doors or windows may be 1cft open needlessly and "short circuit" an otherwise integrated system.
A common problem in the average plant is "air starvation". Exhaust systems throughout the structure may have been well designed for their intended purpose. However, no consideration may have been given to the replacement of exhaust air. As a result, the building may be under severe negative pressure. This situation reduces the efficiency of the exhaust fans and produces unhealthy and uncomfortable working conditions. Substantial economy and efficiency can be obtained by correcting this situation through the use of supply fans or "make-up air" units. Many buildings have adequate exhaust and supply fans to provide a comfortable environment for the occupants. Unfortunately, there may be little control over the distribution of the air to produce the desired results. Good planning will recognize the necessity for proper air distribution and circulation through the occupied areas of the building. Suitable deflectors and baffles can be incorporated where needed. "Booster fans" or air circulators can be positioned to take care of trouble spots and augment the direction and velocity of the air flow. Diffusers may be required lo assist in air distribution. Drafts and dead spots can thus be eliminated. All of these are inexpensive aids that can ensure that a well planned system will achieve its important objectives.
For additional information please refer to http://canadablower.com.
Susan Terlitski
Building Ventilation Designer
Canada Blower Co.
http://canadablower.com/ahu/index.html
http://canadablower.com/hvac/index.html
Susan Terlitski
Building Ventilation Designer
Canada Blower Co.
http://www.canadablower.com/ahu/index.html
http://www.canadablower.com/hvac/index.html
Distributor of Goodyear Water Hoses for all industriesJun 19, 2011 - 12:17:26 AM Chatsworth, CA - June 2011 - Trans American Products http://transamericanproducts.com announced that they have become a full distributor of Goodyear water hoses available in both rubber and pliovic, which is a lighter weight hose. These water hoses are available in black or red rubber and green or bright orange pliovic both with brass fittings. The hoses are available in various lengths and thicknesses to fit the needs of everyone. Trans American always has plenty of stock ready to ship at any time to any place in the United States.... [Read the full story] |
HSE Heat Removal Ventilator - A New DesignJun 12, 2011 - 1:45:01 PM CB Blower Co. has developed a wide range of Heat and Smoke Removal Power Roof Ventilators. These PRVs are especially designed, built and proven by independent test to meet the need of venting hot gases and smoke in the event of fire in commercial and industrial buildings, such as factories, warehouses, parking garages, shopping malls and department stores.... [Read the full story] |
High Pressure Fan Systems by Blowers Depot Co.May 15, 2011 - 11:37:15 AM Blowers Depot Co. has has redesigned its famous blowers-in-series high pressure systems to achieve static pressure, previously unachievable by single stage centrifugal blowers.... [Read the full story] |
Get Employment in AustraliaApr 13, 2011 - 1:57:14 AM Employment- it means the work for which a person get pays and that can be according to the hours, days, month etc. For it there should be at-least two parties in which one would be the employee and the other would be employer. Employee is the person which gives his services and gets pays for that in return and the employer is the person who takes those services and pays for that in return. The employer has full control over the employee. This can be ended by the employer at any time and that too without any reason. Different forms of employment in Australia are present based on different criteria. There are different types of it some of which are given below:- *Full time *Part... [Read the full story] |
Search for articles: |
Latest Articles in All Categories |
Putting Up a Small Commercial Printing Business |
So You Might Be Unemployed And Desire To Become A San Francisco Real Estate Investor Now |
Meditation and Mindfulness: Dealing With Emotion |
CPA Websites: Five Essential Ideas for Composing Convincing Articles |
Set Goals In Order to Come Up With Your Action Plan |
Is the Air in Your Home Safe to Breathe? |
Coarse Fishing Tackle Review: The JW Young 13ft Trotter Rod |
Section 1031 Exchanges For San Diego Real Estate Investors |
Phoenix Real Estate Investing For Highest Possible Earnings |
Legendary are the Volk Racing TE37 Wheels |
Developing the Next Generation Wall Station (ChaseDesk™) for Healthcare - A Case Study |
What are step down transformers? |
Introducing Sharehype, the Revolutionary Tool for Online Marketers |
Rewards To Shopping For Austin Real Estate On The Web |
Hydroponics for Beginners |
Would you like submit your articles and have them approved on a priority status? Find out more about how you can become a Priority author for pennies a day! Click here.
Dime-co.com Home |
|
|
|
|
|
|
|
|
|
|
|
|
|
Disclaimer: Dime-Co.Com is an online information article and video article network. All articles, video articles, comments, and other features herein are for informational purposes only and are provided "as is" without warranties, representations or guarantees of any kind. The views and opinions expressed in an article, comments, links or blogs are the author's own, and not necessarily those of dime-co.com's owners. For full disclaimer, please read our TOS.